SECTION 702 MANHOLES, JUNCTION BOXES & CATCH BASINS

 

MATERIAL

REFERENCE

PURPOSE

SAMPLED BY

MINIMUM

FREQUENCY

MIN. QUANTITY

CERT.

REMARKS

TESTED BY

METHOD

CONTAINER

DISTR.


FOR DETAILS ON CONCRETE TESTS, MIX DESIGNS AND MATERIALS (ADMIXTURES, AGGREGATES, CEMENT AND WATER) SEE SECTION 901 OF THIS MANUAL.
ASPHALTIC VARNISH   702.02
1008.03
Mat. Lab
Accept. Proj. Engr.
S 601
1/batch 1 L
Friction top can

----

 
BACKFILL Density 702.04
701.08(c)(1)
Proj. Engr.
Accept.

------

------

------

----

See Section 701 of this manual.
Granular Material 702.04
701.08(c)(1)
Dist. Lab
Accept.

------

------

------

----

See Section 701 of this manual.
Soil 702.04
701.08(c)(1)
Dist. Lab
Accept.

------

------

------

----

See Section 701 of this manual.
BRICK Sewer 702.02
1004.01
Mat. Lab
Accept. Proj. Engr.
S 601
1/25,000/type* 5 bricks

----

*Visual inspection by Proj. Engr. Sample only if questionable.
COVERS, FRAMES, & GRATES   702.02
1018.04
Const. Fab. Insp.
Accept. Inspected, approved and stamped by Const. Fab. Insp. prior to use. See Section 807 of this manual.

CA

6

Visual inspection by Proj. Engr. Proj. Engr. to receive Form 4148 (Certificate of Cast Iron Covers, Grates, etc.) from Const. Fab. Insp.
GASKET MATERIALS Flexible Plastic Gasket 702.04
1006.06(b)
Mat. Lab
Accept. Inspected and approved by Const. Fab. Insp. prior to use. See Section 701 of this manual.

----

(QPL 4)
Gasket test report lab no. listed on precast unit CD.
GEOTEXTILE FABRIC   702.02
1019.01
Mat. Lab
Prelim.
Source
Approval
Dist. Lab
S 614
1/type/lot/source/
shipment
1 m/roll width of fabric*    ----- *Sample a minimum of 2 m2.
  702.02
1019.01
Mat. Lab
Accept. Proj. Engr.
S 601
1/type/source/shipment 1 m/roll width of fabric*

----

(QPL 61)
*Sample a minimum of 2 m2.
JOINT FILLER   702.04

1005.01(c)

Mat. Lab

Accept.

------

------

------

----

See Section 601
Section 805 of this manual.
METAL WORK PAINT   702.02
1008.05
Mat. Lab
Accept. Proj. Engr.
S 601
1/batch 1 L
Friction top can

----

 
MORTAR Cement, Sand, & Water 702.02
Proj. Engr.
Accept.

------

------

------

----

Visual inspection by Proj. Engr. Sample only if questionable.
PRECAST REINFORCED CONCRETE UNITS   702.02
1016
Const. Fab. Insp.
Accept. Inspected, approved and stamped by Const. Fab. Unit prior to use. See Section 805 of this manual.

CD

1 & 6

Visual inspection by Proj. Engr. CD includes test report no. for gasket materials.
REINFORCEMENT Bars 702.02
1009
Mat. Lab*
Accept. Proj. Engr. or
Const. Fab. Insp.
S 501
1/size/grade/
75 Mg/
source**
1.2 m length

----

*Dist. Lab in Dist. 02.
**If listed on QPL 71, material with a CA (Distr. 1) need not be sampled. Sample for verification if questionable.
Chairs 702.04
805
806.06
Mat. Lab
Accept. Proj. Engr.
S 501
1/type* 1 chair

----

*Visual inspection by Proj. Engr. Sample only if questionable. Chairs with plastic coated tips need not be sampled.
Wire Fabric 702.02
702.04
1009.01(e)
Mat. Lab
Accept. Proj. Engr.*
S 501
1/shipment 1.2 m x 1.2 m

----

*Sampled by Const. Fab. Insp. for precast items.

Return To Table of Contents